pe4383-1 Power Station
DC-rectifiers. Bench Top option with switch mode technology, air-cooled
- Product type:DC rectifiers
- Design:Bench top models
- Cooling:Air cooled
Characteristic values
- Constant current or constant voltage regulation
- Control range for current and voltage: 0% - 100%
- Control deviation within control range of 2% - 100%: Current < 0.5% (in relation to nom. current), voltage < 0.5% (in relation to nom. voltage)
- Ripple < 0.5% (in relation to nom. DC output voltage) within a frequency range of 0 - 300Hz and within the control range of 2% - 100%
- Efficiency typical: up to 95 % at nominal output power
- Power factor: 0,95
- Inrush current limiter
- Over temperature protection
- Current and voltage preset
- Programmable control unit
- Large 3-line LCD display
- Keypad for operation and programming
- Integrated Ampere-hour counter (totalizer) (preset counter and other functions optional available)
- Mains supply: 3 x 400 V +/- 10 % / 50-60 Hz without N 1x230V+/-10%/ 50-60HzwithN (other voltages on request)
Cooling
- Optimized cooling air guiding,
- air consumption max. 100m3/h
- Cooling air outlet in front panel (turned air flow on request)
- Ambient temperature 5 - 35°C (other on request)
Design
- Compact desktop unit
- Protection grade IP31; sealed air duct
- Casing powder coated colour RAL 9018 (Standard)
- Aluminium front panel with polycarbonat film
- DC connection in back panel
Technical data
current | 300 A |
---|---|
power | 6 kW |
voltage | 600 V |