pe5110 Power Station

DC-rectifiers. Floor mounted cabinet with switch mode technology, air-cooled

  • Product type:DC rectifiers
  • Design:Cabinet models
  • Cooling:Air cooled

Variable output range

  • the output range can be individually multiplied

Characteristic values

  • Constant current and voltage control
  • Regulation range for current and voltage: 0 - 100 %
  • Control deviation within control range of 2% - 100%: Current < 1% (in relation to nom. current), voltage < 0.5% (in relation to nom. voltage)
  • Ripple < 1% (in relation to nom. DC output voltage) within a frequency range of 0 - 300Hz and within the control range of 2% - 100%
  • Efficiency typical: up to 95 % at nominal output power
  • Power factor: 0,95
  • Inrush current limiter
  • Over temperature protection
  • Pulse operation optional
  • Mains supply: standard 3 x 400 V +/- 10 % / 50-60 Hz (other voltages on request)

Cooling

  • Air cooled, air consumption max. 2000m3/h (depending on output power)
  • Ambient temperature 35°C (other on request)

Design

  • Compact Rittal cabinet; powder coated: IP20
  • Powder coated, RAL 7035
  • DC connector via DC output bus bars in the top of the cabinet

Technical data

current 5 000 A
power 100 kW
voltage 1 000 V

Request for quotation

Please calculate 1 plus 4.

Request data sheet